# HunterLab launches Vista® L2 with an extended 710 nm measurement range

- Link: https://www.thailand-business-news.com/pr-news/hunterlab-launches-vista-l2-with-an-extended-710-nm-measurement-range
- Published: 2026-07-21T11:30:00+07:00
- Author: PR Newswire

|   |

**The next-generation Vista pairs Essentials L2, the most advanced color analysis
software in the category, with far more onboard computing, all without changing 
existing methods or accessories**

RESTON, Va., July 21, 2026 /PRNewswire/ — HunterLab, the world’s true measure of
color, today announced [Vista^(®) L2](https://edge.prnewswire.com/c/link/?t=0&l=en&o=4734050-1&h=1879236009&u=https%3A%2F%2Fwww.hunterlab.com%2Fen%2Fproducts%2Fbenchtop-spectrophotometers%2Fvista-l2%2F&a=Vista%C2%AE+L2),
the next generation of its transmission color and haze spectrophotometer for transparent
and translucent liquids and solids. Vista L2 extends the spectral range to 710 nm,
adds Essentials L2, the most advanced color analysis software in the industry, and
expands processing power and storage. The result is more capability for quality 
control teams in beverages, edible oils, liquid chemicals, pharmaceuticals, translucent
plastic preforms, and environmental testing.

 [⌊HunterLab Vista L2⌉](https://mmx.prnasia.com/media/MS1884852/HunterLab-HunterLab-Vista-L2.jpg?id=OA2771836&p=medium600)

HunterLab Vista L2

The wider range sharpens the separation of true color, measured as absorbance, from
haze, measured as light scattering. That clarity helps manufacturers catch early-
stage instability in liquid products and judge color stability with more confidence.
The 710 nm reach also enables chlorophyll measurement at 630, 670, and 710 nm, aligned
to AOCS Cc 13d-55, a method used to track oxidation and protect shelf life in edible
oils.

"Quality teams are being asked to measure more, on tighter timelines, without adding
instruments or headcount," said Bob Weaver, President at HunterLab. "Vista L2 was
built for that reality. It widens what a single instrument can measure while running
the same methods and accessories our customers already use, so the upgrade adds 
capability without disruption."

Vista L2 builds on the established Vista platform, retaining its transmission geometry,
full-spectrum LED illumination, and touchscreen interface. New and enhanced features
include 32 GB of onboard storage, enough for millions of measurements, HDMI output
for viewing results on external displays, and a built-in wavelength verification
standard that keeps performance consistent. Essentials L2 updates by flash drive
or direct internet connection.

Vista L2 is the only transmission instrument to apply the Beer-Lambert Law with 
the precision needed to report absolute color from standard cells and vials. It 
reports edible oils automatically at 5.25 inch or 1 inch pathlengths and reads APHA
color in smaller cells than competing systems require, reducing reliance on costly
specialty cells. Interchangeable holders and base plates, in Multi-Functional, Precision,
and Self-Centering options, position liquids, vials, cuvettes, translucent plastic
preforms, films, and flow-through samples with magnetic attachments and locating
pins for repeatable results.

Vista L2 is available now. Additional information and demonstration requests are
available at [https://www.hunterlab.com/en/contact/](https://edge.prnewswire.com/c/link/?t=0&l=en&o=4734050-1&h=521661696&u=https%3A%2F%2Fwww.hunterlab.com%2Fen%2Fcontact%2F&a=https%3A%2F%2Fwww.hunterlab.com%2Fen%2Fcontact%2F).

About HunterLab

Founded in 1952, HunterLab is a global leader in color and appearance measurement
[solutions for industries](https://edge.prnewswire.com/c/link/?t=0&l=en&o=4734050-1&h=1285659027&u=https%3A%2F%2Fedge.prnewswire.com%2Fc%2Flink%2F%3Ft%3D0%26l%3Den%26o%3D4539584-1%26h%3D3754059219%26u%3Dhttps%253A%252F%252Fwww.hunterlab.com%252Fen%252Findustries%252F%26a%3Dsolutions%2Bfor%2Bindustries&a=solutions+for+industries)
including food and beverage, plastics, chemicals, and pharmaceuticals. With instruments
trusted in more than 75 countries, HunterLab continues to advance the science of
color through innovation, precision, and customer partnership.

Media Contact:
HunterLab Marketing[marketing@hunterlab.com](https://www.thailand-business-news.com/pr-news/marketing@hunterlab.com)
[www.hunterlab.com](https://edge.prnewswire.com/c/link/?t=0&l=en&o=4734050-1&h=2199592857&u=https%3A%2F%2Fedge.prnewswire.com%2Fc%2Flink%2F%3Ft%3D0%26l%3Den%26o%3D4539584-1%26h%3D4116550583%26u%3Dhttps%253A%252F%252Fwww.hunterlab.com%252F%26a%3Dwww.hunterlab.com&a=www.hunterlab.com)

---

  |  This article was produced by Cision PR Newswire, our trusted news partner. The views expressed and the content presented here are solely those of the author and may not fully reflect the opinions of Thailand Business News. |

---

 
**Read the original article :** [HunterLab launches Vista® L2 with an extended 710 nm measurement range ](http://www.prnasia.com/story/archive/5007107_AE07107_0?rand=184833)
